1.
BMC Neurol ; 21(1): 292, 2021 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-34311729

RESUMO

PURPOSE: To obtain normal ranges for the inner diameters of the carotid arteries. METHODS: This retrospective analysis included consecutive patients with disease-free carotid arteries who had undergone 3D-DSA at two hospitals in Nanning, Guangxi, between March 2013 and March 2018. Demographic and clinical characteristics, including Essen Stroke Risk Score (ESRS), were extracted from the medical records. The 3D-DSA data were used to calculate the inner diameters of the carotid arteries. RESULTS: The analysis included 1182 patients (837 males) aged 58.81 ± 11.02 years. The inner diameters of the proximal carotid sinus (CS), CS bulge, distal CS, and common carotid artery (CCA) were larger on the right than on the left (P < 0.05). The inner diameters of the proximal CS, CS bulge, distal CS, and CCA on both sides were larger for males than females (P < 0.05). The inner diameters of the proximal CS, CS bulge, and distal CS on both sides were smaller for patients aged > 65 years than for patients aged ≤ 55 years (P < 0.05). Right CCA inner diameter did not vary with age, whereas left CCA inner diameter was larger for patients aged > 55 years than for patients aged ≤ 45 years (P < 0.05). The inner diameters of the proximal CS, CS bulge, and distal CS on both sides were smaller for patients with ESRS ≥ 3 than those with ESRS < 3 (P < 0.05). CONCLUSION: This study provides reference values for the internal diameters of normal carotid arteries. Carotid artery diameters varied with side, sex, and age.


Assuntos
Angiografia Digital , Artérias Carótidas , Adulto , Idoso , Angiografia Digital/instrumentação , Angiografia Digital/métodos , Artérias Carótidas/anatomia & histologia , Artérias Carótidas/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Valores de Referência , Estudos Retrospectivos
2.
Radiology ; 295(2): 390-396, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32125257

RESUMO

Background Spinal digital subtraction angiography (DSA) exposes patients and operators to substantial amounts of radiation. Antiscatter grid (ASG) removal is used to decrease radiation exposure but may reduce image quality. Purpose To determine whether ASG removal during spinal DSA in adults reduces radiation dose while maintaining diagnostic image quality and whether dose reduction is related to body mass index (BMI). Materials and Methods This Health Insurance Portability and Accountability Act-compliant prospective study included adults undergoing spinal DSA between January and December 2016. Each procedure included an additional angiographic acquisition performed twice, once with and once without ASG, either documenting the artery of Adamkiewicz (no pathology group) or the condition leading to the procedure (pathology group). Dose differences between study acquisitions and the influence of BMI were evaluated via paired t test. Two neurointerventionalists blinded to acquisition protocols were asked to independently evaluate a sample of 40 study acquisitions (20 with ASG, 20 without ASG) from 20 randomly selected participants to (a) rate image quality, (b) categorize findings, and (c) determine whether images had been obtained with or without ASG. Percentage agreement on image quality, findings categorization, and ability to correctly identify the acquisition protocol was calculated for both readers. Results Fifty-three participants (mean age ± standard deviation, 51 years ± 15.2; 32 men) were evaluated. ASG removal reduced the mean dose per acquisition by approximately 33% (mean dose-area product and air kerma decreased from 202 to 135.6 µGy/m2 and from 35.3 to 24 mGy, respectively; P < .001) independently of BMI (P = .3). Both readers evaluated all images (40 of 40) as being of diagnostic quality and correctly categorized findings in 19 of 20 (95%) cases. Overall percentage agreement for correct protocol identification was 60% (12 of 20) for grid-in and 45% (nine of 20) for grid-out images. Conclusion Antiscatter grid removal during spinal digital subtraction angiography decreased participants' radiation exposure while preserving diagnostic image quality. © RSNA, 2020.


Assuntos
Angiografia Digital/instrumentação , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica/instrumentação , Doenças da Coluna Vertebral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação , Espalhamento de Radiação
3.
BMJ Case Rep ; 12(7)2019 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-31278200

RESUMO

Pipeline embolisation device (PED) 'twisting' is an intra-operative complication that manifests with the appearance of a 'figure-8' in perpendicular planes on digital subtraction angiography. A twisted PED causes narrowing and/or complete occlusion of the vessel lumen and poses significant risks for thrombus formation and downstream ischaemia. Here, we present a case in which three unique PED implants become twisted during pipeline embolisation of a large fusiform internal carotid artery aneurysm. The twists were remediated by balloon angioplasty and a combination of techniques that allowed the PED to rotate and restore its original axis. Six-month and twelve-month follow-up angiography demonstrated complete aneurysm occlusion with preservation of the parent vessel, proving that proper remediation of PED twisting can still result in successful long-term outcomes.


Assuntos
Angiografia Digital/efeitos adversos , Angioplastia com Balão/métodos , Embolização Terapêutica/efeitos adversos , Aneurisma Intracraniano/cirurgia , Angiografia Digital/instrumentação , Artéria Carótida Interna/cirurgia , Embolização Terapêutica/instrumentação , Humanos , Pessoa de Meia-Idade
4.
J Neurointerv Surg ; 11(10): 1036-1039, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30878951

RESUMO

BACKGROUND: Endovascular technological advances have revolutionized the field of neurovascular surgery and have become the mainstay of treatment for many cerebrovascular pathologies. Digital subtraction angiography (DSA) is the 'gold standard' for visualization of the vasculature and deployment of endovascular devices. Nonetheless, with recent technological advances in optics, angioscopy has emerged as a potentially important adjunct to DSA. Angioscopy can offer direct visualization of the intracranial vasculature, and direct observation and inspection of device deployment. However, previous iterations of this technology have not been sufficiently miniaturized or practical for modern neurointerventional practice. OBJECTIVE: To describe the evolution, development, and design of a microangioscope that offers both high-quality direct visualization and the miniaturization necessary to navigate in the small intracranial vessels and provide examples of its potential applications in the diagnosis and treatment of cerebrovascular pathologies using an in vivo porcine model. METHODS: In this proof-of-concept study we introduce a novel microangioscope, designed from coherent fiber bundle technology. The microangioscope is smaller than any previously described angioscope, at 1.7 F, while maintaining high-resolution images. A porcine model is used to demonstrate the resolution of the images in vivo. RESULTS: Video recordings of the microangioscope show the versatility of the camera mounted on different microcatheters and its ability to navigate external carotid artery branches. The microangioscope is also shown to be able to resolve the subtle differences between red and white thrombi in a porcine model. CONCLUSION: A new microangioscope, based on miniaturized fiber optic technology, offers a potentially revolutionary way to visualize the intracranial vascular space.


Assuntos
Angioscopia/tendências , Desenho de Equipamento/tendências , Neuronavegação/tendências , Estudo de Prova de Conceito , Angiografia Digital/instrumentação , Angiografia Digital/métodos , Angiografia Digital/tendências , Angioscopia/instrumentação , Angioscopia/métodos , Animais , Desenho de Equipamento/métodos , Feminino , Tecnologia de Fibra Óptica/instrumentação , Tecnologia de Fibra Óptica/métodos , Tecnologia de Fibra Óptica/tendências , Humanos , Neuronavegação/instrumentação , Neuronavegação/métodos , Suínos
5.
PLoS One ; 13(12): e0208446, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30532277

RESUMO

About one third of all deaths worldwide can be traced back to cardiovascular diseases. An interventional radiology procedure for their diagnosis is Digital Subtraction Angiography (DSA). An alternative to DSA is K-Edge subtraction (KES) imaging, which has been shown to be advantageous for moving organs and eliminating image artifacts caused by patient movement. As highly brilliant, monochromatic X-rays are required for this method, it has been limited to synchrotron facilities so far, restraining the feasibility in clinical routine. Compact synchrotron X-ray sources based on inverse Compton scattering, which have been evolving substantially over the past decade, provide X-rays with sufficient brilliance that meet spatial and financial requirements affordable in laboratory settings or for university hospitals. In this work, we demonstrate a first proof-of-principle K-edge subtraction imaging experiment using the Munich Compact Light Source (MuCLS), the first user-dedicated installation of a compact synchrotron X-ray source worldwide. It is shown experimentally that the technique of KES increases the visibility of small blood vessels overlaid by bone structures.


Assuntos
Angiografia Digital , Angiografia Coronária/instrumentação , Angiografia Coronária/métodos , Síncrotrons , Raios X , Angiografia Digital/instrumentação , Angiografia Digital/métodos , Animais , Desenho de Equipamento , Estudos de Viabilidade , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Caixa Torácica/diagnóstico por imagem , Razão Sinal-Ruído , Suínos
6.
J Vasc Surg ; 68(6): 1889-1896, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30473030

RESUMO

OBJECTIVE: The objective of this study was to analyze radiation risk to patients during endovascular aneurysm repair (EVAR) using mobile C-arm (MA) or fixed C-arm (FA) fluoroscopes and to describe the dose distribution during the different phases of the procedure. METHODS: Patients treated with EVAR using a single stent graft system between November 2009 and June 2016 were included in this study. The patients were divided into one of two groups (MA or FA) according to the type of C-arm used in the procedure. Data regarding patients' demographics and the total amount of contrast agent (CA) used, dose-area product, and fluoroscopy time for the procedures were prospectively recorded. Based on the dose report from the FA system, five standard and two optional phases of the procedure were identified to determine the dose distribution. RESULTS: Overall, 160 patients were included (mean age, 73.30 ± 8.97 years; 146 men); of these, 107 were treated with an MA system and 53 were treated with an FA system. The mean amounts of CA used were 108.55 ± 42.28 mL in the MA group and 85.37 ± 38.79 mL in the FA group (P = .0014). The mean total dose-area product values were 49.93 ± 38.06 Gy·cm2 in the MA group and 168.34 ± 146.92 Gy·cm2 in the FA group (P < .0001). There was no significant difference in fluoroscopy time between the groups. Per-phase analysis demonstrated that identification of the proximal landing zone and main body deployment required the most radiation, accounting for 24% of the total radiation dose. Overall, 47.6% of the exposure was due to digital subtraction angiography. CONCLUSIONS: Use of an FA system can significantly reduce the amount of CA needed but may also lead to higher radiation doses in EVAR procedures. Dose monitoring remains crucial for the safety of both patients and operators. A detailed analysis of dose distribution is possible with modern systems, which may improve the quality of monitoring in the future.


Assuntos
Angiografia Digital/instrumentação , Aorta/diagnóstico por imagem , Aorta/cirurgia , Aortografia/instrumentação , Implante de Prótese Vascular , Procedimentos Endovasculares , Doses de Radiação , Exposição à Radiação , Radiografia Intervencionista/instrumentação , Tomógrafos Computadorizados , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital/efeitos adversos , Aortografia/efeitos adversos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Desenho de Equipamento , Feminino , Fluoroscopia , Humanos , Masculino , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Monitoramento de Radiação , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
7.
J Clin Neurosci ; 58: 20-24, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30454690

RESUMO

BACKGROUND AND PURPOSE: Flow-diversion therapy (FDT) for large and complex intracranial aneurysms is effective and considered superior to primary coil embolization. Data evaluating common treatment with both FDT and coiling continues to emerge, but information on outcomes remains scarce. This study aims to examine further the efficiency and outcomes correlated with joint FDT using pipeline embolization device (PED) and coiling compared to PED-alone in treating intracranial aneurysms. MATERIALS AND METHODS: Comparative review and analysis of aneurysm treatment with PED in 416 subjects were conducted. Joint modality, PED, and coiling were compared to PED-alone for aneurysm occlusion, recurrence, retreatment, thromboembolic or hemorrhagic events, and functional outcome using the modified Rankin Scale. Data on patient demographics, aneurysm characteristics, clinical and angiographic follow up, were also collected. Both univariate analysis and multivariate logistic regression modeling using mixed-effects were performed. RESULTS: Total of 437 aneurysms were treated using PED of which 74 were managed with both PED and coiling. Average patient-age was 56 years, the majority were men (85%), an average aneurysm size was 9 mm, and the majority were saccular aneurysms (84%). Larger aneurysm size was associated with a poor outcome in patients with unruptured aneurysms (OR = 1.06). Adjusted regression analyses revealed no differences between treatment groups in thromboembolic or hemorrhagic events, aneurysm occlusion rate, residual flow on follow up angiography, or functional outcome. CONCLUSIONS: Treatment of intracranial aneurysms with joint PED and coiling was safe with no increase in complications when compared to PED alone. Aneurysm occlusion rates and functional outcome with PED and coiling stays comparable to treatment with PED-alone.


Assuntos
Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Stents Metálicos Autoexpansíveis , Adulto , Idoso , Angiografia Digital/instrumentação , Angiografia Digital/métodos , Prótese Vascular , Embolização Terapêutica/instrumentação , Procedimentos Endovasculares/instrumentação , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/administração & dosagem , Retratamento/instrumentação , Retratamento/métodos , Estudos Retrospectivos , Resultado do Tratamento
8.
Chirurg ; 87(12): 1015-1024, 2016 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-27796416

RESUMO

Modern intraoperative techniques of visualization are increasingly being applied in general and visceral surgery. The combination of diverse techniques provides the possibility of multidimensional intraoperative visualization of specific anatomical structures. Thus, it is possible to differentiate between normal tissue and tumor tissue and therefore exactly define tumor margins. The aim of intraoperative visualization of tissue that is to be resected and tissue that should be spared is to lead to a rational balance between oncological and functional results. Moreover, these techniques help to analyze the physiology and integrity of tissues. Using these methods surgeons are able to analyze tissue perfusion and oxygenation. However, to date it is not clear to what extent these imaging techniques are relevant in the clinical routine. The present manuscript reviews the relevant modern visualization techniques focusing on intraoperative computed tomography and magnetic resonance imaging as well as augmented reality, fluorescence imaging and optoacoustic imaging.


Assuntos
Diagnóstico por Imagem/métodos , Monitorização Intraoperatória/métodos , Imagem Multimodal/instrumentação , Imagem Multimodal/métodos , Procedimentos Cirúrgicos Operatórios/métodos , Angiografia Digital/instrumentação , Angiografia Digital/métodos , Sistemas Computacionais , Diagnóstico por Imagem/instrumentação , Desenho de Equipamento , Humanos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Monitorização Intraoperatória/instrumentação , Neoplasias/patologia , Neoplasias/cirurgia , Imagem Óptica/instrumentação , Imagem Óptica/métodos , Técnicas Fotoacústicas/instrumentação , Técnicas Fotoacústicas/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Realidade Virtual
9.
Vasc Endovascular Surg ; 50(3): 164-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27000390

RESUMO

Leiomyosarcoma of the vascular origin is a rare malignant tumor. It originates from the smooth muscle cells of the media with intra- or extraluminal growth, and in most cases it arises in the inferior vena cava. The diagnosis is often delayed because the clinical symptoms of this disease are often nonspecific. Accurate diagnosis of inferior vena cava leiomyosarcoma (IVCLMS) needs histologic confirmation. We report a case of IVCLMS histologically confirmed by aspiration biopsy with a catheter during digital subtraction angiography presenting with pulmonary emboli in a 65-year-old man.


Assuntos
Angiografia Digital/instrumentação , Biópsia por Agulha/instrumentação , Leiomiossarcoma/diagnóstico por imagem , Leiomiossarcoma/patologia , Dispositivos de Acesso Vascular , Neoplasias Vasculares/diagnóstico por imagem , Neoplasias Vasculares/patologia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/patologia , Idoso , Anticoagulantes/uso terapêutico , Quimioterapia Adjuvante , Angiografia por Tomografia Computadorizada , Diagnóstico Diferencial , Humanos , Leiomiossarcoma/complicações , Leiomiossarcoma/cirurgia , Masculino , Flebografia/métodos , Valor Preditivo dos Testes , Embolia Pulmonar/etiologia , Resultado do Tratamento , Neoplasias Vasculares/complicações , Neoplasias Vasculares/cirurgia , Veia Cava Inferior/cirurgia , Trombose Venosa/etiologia
10.
Neuroradiology ; 58(7): 673-8, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26970990

RESUMO

INTRODUCTION: The purpose of this experimental phantom study was to compare radiation doses imparted to patients undergoing classical two-plane digital subtraction angiography (2-plane DSA) and 3D rotational angiography in interventional neuroradiology. METHODS: Thermoluminescence dosimeter (TLD) measurements were performed at an anthropomorphic phantom using a digital interventional angiography system. Two-plane DSA included posterior/anterior (PA) and lateral (LAT) projections (frame-rate, 7.6 frames (PA) and 9.8 frames (LAT) for a scan time of approximately 8 s; image intensifier 27 cm (PA) and 25 cm (LAT)). For 3D rotational angiography, 122 images were acquired from one single image run with the imaging system rotating 240° around the phantom's head (image intensifier 37 cm). RESULTS: Effective dose was 0.4 mSv for 2-plane DSA compared to 0.1 mSv for 3D rotational angiography. Organ doses were approximately two to five times higher for classical 2-plane technique compared to the 3D rotational angiography, respectively: brain (11.4 vs. 2.4 mSv), eye lens (4.5 vs.1 mSv), salivary glands (7 vs. 1,7 mSv), oral mucosa (2.7 vs.0.9 mSv), thyroid (0.5 vs. 0.2 mSv), thymus (0.2 vs. 0.05 mSv), bone marrow within imaged region (1 vs. 0.2 mSv), oesophagus (0.07 vs. 0.03 mSv), endotracheal system (2.6 vs. 0.7 mSv) and skeletal components in the imaged region (0.7 vs. 0.2 mSv). CONCLUSION: Three-dimensional rotational angiography clearly reduces radiation doses compared to the classical 2-plane technique. Replacement of additional 2-plane DSA projections with 3D rotational angiography will lead to a remarkable decrease in patient radiation dose, without loss of image quality. Thus, we recommend routine application of 3D rotational angiography, in particular for diagnostic assessment of aneurysm morphology.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Imageamento Tridimensional/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação/análise , Angiografia Digital/instrumentação , Angiografia Cerebral/instrumentação , Angiografia por Tomografia Computadorizada/instrumentação , Feminino , Humanos , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente
11.
J Endovasc Ther ; 23(1): 130-8, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26763260

RESUMO

PURPOSE: To evaluate the effect of radiation dose reduction with the Allura ClarityIQ image processing technology for fixed C-arms in comparison with a mobile C-arm and an Allura fixed C-arm without ClarityIQ technology during endovascular aneurysm repair (EVAR) procedures. METHODS: Radiation dose data from 85 patients (mean age 74.2±7.8 years; 68 men) undergoing EVAR with mobile and fixed C-arm fluoroscopy were retrospectively analyzed. The radiation dose parameters included the kerma area product (KAP), fluoroscopic time (FT), and number of digital subtraction angiography (DSA) frames (FrDSA). KAPtotal consisted of KAPfluoro (KAP for fluoroscopic imaging) and KAPDSA (KAP for DSA and single shots). Linear regression analysis was used to explore differences in the association of KAP with the FT, FrDSA, and body mass index (BMI) among the 3 C-arms. RESULTS: The mean KAPtotal values for mobile, Allura C-arm, and AlluraClarity C-arm for noncomplex EVARs were 56±39, 245±142, and 157±120 Gy·cm(2) (p<0.001); for complex EVARs, the values were 110±43, 874±653, and 598±319 Gy·cm(2) (p<0.001), respectively. On average, KAPfluoro tripled when the mobile C-arm was replaced by the fixed C-arm. There were no significant differences in the KAPfluoro adjusted for the FT between Allura and AlluraClarity (p=0.69). However, there was a major 61% reduction in KAPDSA from 1.36 Gy·cm(2) per DSA frame for Allura to 0.54 Gy·cm(2) per DSA frame with AlluraClarity (p=0.03). For the mobile C-arm, BMI was not associated with KAP (p=0.13). The associations of BMI with KAPfluoro and KAPDSA were significant for both fixed C-arms but were more robust for Allura compared to AlluraClarity (p=0.02 for KAPfluoro and p<0.001 for KAPDSA). CONCLUSION: Changing a mobile C-arm for a fixed C-arm in a hybrid operating suite increased the average intraoperative dose during EVAR. Upgrading the Allura fixed C-arm with ClarityIQ technology resulted in a 61% reduction in the radiation per DSA frame.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Salas Cirúrgicas , Doses de Radiação , Exposição à Radiação/prevenção & controle , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Radiografia Intervencionista/instrumentação , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital/instrumentação , Aortografia/instrumentação , Índice de Massa Corporal , Desenho de Equipamento , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Fatores de Risco
12.
J Neurosurg ; 124(6): 1716-25, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26544772

RESUMO

OBJECT The authors compared the image quality and diagnostic sensitivity and specificity of 7.0-T and 3.0-T MRI and time-of-flight (TOF) MR angiography (MRA) in patients with moyamoya disease (MMD). METHODS MR images of 15 patients with ischemic-type MMD (8 males, 7 females; age 13-48 years) and 13 healthy controls (7 males, 6 females; age 19-28 years) who underwent both 7.0-T and 3.0-T MRI and MRA were studied retrospectively. The main intracranial arteries were assessed by using the modified Houkin's grading system (MRA score). Moyamoya vessels (MMVs) were evaluated by 2 grading systems: the MMV quality score and the MMV area score. Two diagnostic criteria for MMD were used: the T2 criteria, which used flow voids in the basal ganglion on T2-weighted images, and the TOF criteria, which used the high-intensity areas in the basal ganglion on source images from TOF MRA. All data were evaluated by 2 independent readers who were blinded to the strength field and presence or absence of MMD. Using conventional angiography as the gold standard, the sensitivity and specificity of 7.0-T and 3.0-T MRI/MRA in the diagnosis of MMD were calculated. The differences between 7.0-T and 3.0-T MRI and MRA were statistically compared. RESULTS No significant differences were observed between 7.0-T and 3.0-T MRA in MRA score (p = 0.317) or MRA grade (p = 0.317). There was a strong correlation between the Suzuki's stage and MRA grade in both 3.0-T (rs = 0.930; p < 0.001) and 7.0-T (rs = 0.966; p < 0.001) MRA. However, MMVs were visualized significantly better on 7.0-T than on 3.0-T MRA, suggested by both the MMV quality score (p = 0.001) and the MMV area score (p = 0.001). The correlation between the Suzuki's stage and the MMV area score was moderate in 3.0-T MRA (rs = 0.738; p = 0.002) and strong in 7.0-T MRA (rs = 0.908; p < 0.001). Moreover, 7.0-T MR images showed a greater capacity for detecting flow voids in the basal ganglion on both T2-weighted MR images (p < 0.001) and TOF source images (p < 0.001); 7.0-T MRA also revealed the subbranches of superficial temporal arteries much better. Receiver operating characteristic curve analysis showed that, according to the T2 criteria, 7.0-T MRI/MRA was more sensitive (sensitivity 1.000; specificity 0.933) than 3.0-T MRI/MRA (sensitivity 0.692; specificity 0.933) in diagnosing MMD; based on the TOF criteria, 7.0-T MRI/MRA was more sensitive (1.000 vs 0.733, respectively) and more specific (1.000 vs 0.923, respectively) than 3.0-T MRI/MRA. CONCLUSIONS Compared with 3.0-T MRI/MRA, 7.0-T MRI/MRA detected and delineated MMVs more clearly and provided higher diagnostic sensitivity and specificity, although it did not show significant improvement in depicting main intracranial arteries. The authors speculate that 7.0-T MRI/MRA is a promising technique in the diagnosis of MMD because it is noninvasive compared with conventional angiography and it is more sensitive than 3.0-T MRI/MRA.


Assuntos
Angiografia Cerebral/instrumentação , Angiografia Cerebral/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Doença de Moyamoya/diagnóstico por imagem , Adolescente , Adulto , Angiografia Digital/instrumentação , Angiografia Digital/métodos , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Adulto Jovem
13.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 71(9): 758-63, 2015 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-26400559

RESUMO

In vascular access intervention therapy (VAIVT), carbon dioxide is used as negative contrast medium for patients with iodine allergy or for those who have vascular access but not started with dialysis yet and have not endangered their remaining kidney function. To capture the movement of jet-injected carbon dioxide during the carbon dioxide angiography, we performed imaging at a rate of 15 frames per second. This method has a higher level of radiation exposure than angiography using an iodine contrast medium. Therefore we developed a catheter with 20 helical side holes in the tip (carbon dioxide angiography catheter), which allows large numbers of tiny bubbles to be generated simultaneously. In our study, we evaluate whether the use of this catheter can reduce the number of frames taken per second thus reducing the radiation exposure. A comparative experiment with existing angiography catheters with no side holes suggested that the use of this carbon dioxide angiography catheter to be useful for reducing the radiation exposure to patients and operators. Moreover, angiography using this catheter is highly useful from viewpoint of improving the stenotic vesselvisibility and reducing the side effects of using carbon dioxide, and we expect that the carbon dioxide angiography method is effective for patients and operators.


Assuntos
Angiografia Digital/métodos , Dióxido de Carbono , Angiografia Digital/instrumentação , Cateteres , Meios de Contraste , Desenho de Equipamento , Humanos , Dispositivos de Acesso Vascular
14.
Catheter Cardiovasc Interv ; 86(7): 1228-33, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26389534

RESUMO

BACKGROUND: The AVERT(TM) Contrast Modulation System (AVERT) (Osprey Medical, MN) is designed to reduce contrast volume administration during angiography. The AVERT provides an adjustable resistance circuit which decreases the pressure head delivering contrast towards the patient. The AVERT has not been previously studied in patients undergoing peripheral digital subtraction angiography (DSA). The purpose of this study was (1) to evaluate contrast savings with the AVERT and (2) to evaluate the ability to generate clinically acceptable DSA images in the process. To better define the mechanism of action in the peripheral circulation, we also developed a bench model to study the effects of the AVERT on the hydrodynamics of contrast delivery. METHODS: Patients undergoing lower extremity DSA (diagnostic or intervention, sheath or catheter) were studied. The following variables were recorded for each injection: starting control syringe contrast volume, contrast volume injected towards patient, contrast volume returned to AVERT reservoir, net contrast administered to the patient and % savings. The AVERT resistance was adjusted manually based on operator's discretion--balancing image quality and contrast savings. RESULTS: About 408 DSA angiographic sequences were obtained in 22 patients undergoing 29 procedures. Almost 68% of the patients had chronic kidney disease. An 82% presented with critical limb ischemia, 18% had claudication. There was an overall 37% ± 14% savings of contrast (31% for diagnostic DSA, 40% for interventional procedures). Overall 91% of all images were acceptable for clinical decision making. Specifically, 94% of diagnostic and 87% of interventional images were acceptable. Injection through a 4 Fr catheter (77% acceptable) resulted in poorer image quality as compared to a 5 Fr catheter (96% acceptable). Image quality for 5, 6, and 7 Fr sheath injections was 86%, 91%, 98%, respectively. The bench model of peripheral angiography demonstrated a significant reduction in reflux of contrast proximal to the end of the catheter without loss of antegrade image quality - confirming the in vivo findings. CONCLUSIONS: We demonstrate that the use of the AVERT device during peripheral angiography results in significant contrast savings without compromising image quality.


Assuntos
Angiografia Digital/instrumentação , Cateterismo Periférico/instrumentação , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares/instrumentação , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Dispositivos de Acesso Vascular , Idoso , Angiografia Digital/efeitos adversos , Cateterismo Periférico/efeitos adversos , Meios de Contraste/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Modelos Cardiovasculares , Doença Arterial Periférica/complicações , Valor Preditivo dos Testes , Punções , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Fatores de Risco
15.
Neurol Med Chir (Tokyo) ; 55(6): 505-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26041625

RESUMO

Intraoperative angiography (IOA) is employed for the treatment of the complicated cases in neurological surgery. The IOA is usually performed with OEC portable digital subtraction angiography (DSA) unit. We are performing IOA with portable fluoroscopy unit with simple DSA function and report its usefulness on neurosurgical treatment. IOA or hybrid treatment with mobile fluoroscopy system was performed for 9 cases [cerebral arteriovenous malformation (AVM), 3; cranial dural arteriovenous fistula (AVF), 2; and spinal AVM/AVF, 4]. Thus, ex vivo analysis was performed comparing image quality of portable fluoroscopy unit and conventional DSA system. Although the resolution of portable fluoroscopy unit is not so high compared to conventional DSA system, the existence of the vascular lesions such as cerebral aneurysm, cerebral AVM, and spinal dural AVF were detected. The operation of portable fluoroscopy unit was simple and no special assistance was required. The complication related to the catheterization or IOA did not occur. IOA with portable fluoroscopy unit was useful for the identification of vascular lesion and has advantage on the cost benefit.


Assuntos
Angiografia Digital , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Angiografia Cerebral , Cuidados Intraoperatórios , Idoso , Angiografia Digital/instrumentação , Malformações Vasculares do Sistema Nervoso Central/cirurgia , Angiografia Cerebral/instrumentação , Fluoroscopia/instrumentação , Humanos , Cuidados Intraoperatórios/instrumentação , Masculino , Pessoa de Meia-Idade
16.
PLoS One ; 10(6): e0130661, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26098622

RESUMO

BACKGROUND: Repetitive administration of medication or contrast agents is frequently performed in mice. The introduction of vascular access mini-ports (VAMP) for mice allows long-term vascular catheterization, hereby eliminating the need for repeated vessel puncture. With catheter occlusion being the most commonly reported complication of chronic jugular vein catheterization, we tested whether digital subtraction angiography (DSA) can be utilized to evaluate VAMP patency in mice. METHODS: Twenty-three mice underwent catheterization of the jugular vein and subcutaneous implantation of a VAMP. The VAMP was flushed every second day with 50 µL of heparinized saline solution (25 IU/ml). DSA was performed during injection of 100 µL of an iodine based contrast agent using an industrial X-ray inspection system intraoperatively, as well as 7±2 and 14±2 days post implantation. RESULTS: DSA allowed localization of catheter tip position, to rule out dislocation, kinking or occlusion of a microcatheter, and to evaluate parent vessel patency. In addition, we observed different ante- and retrograde collateral flow patterns in case of jugular vein occlusion. More exactly, 30% of animals showed parent vessel occlusion after 7±2 days in our setting. At this time point, nevertheless, all VAMPs verified intravascular contrast administration. After 14±2 days, intravascular contrast injection was verified in 70% of the implanted VAMPs, whereas at this point of time 5 animals had died or were sacrificed and in 2 mice parent vessel occlusion hampered intravascular contrast injection. Notably, no occlusion of the catheter itself was observed. CONCLUSION: From our observations we conclude DSA to be a fast and valuable minimally invasive tool for investigation of catheter and parent vessel patency and for anatomical studies of collateral blood flow in animals as small as mice.


Assuntos
Angiografia Digital/métodos , Cateterismo Venoso Central/métodos , Cateteres Venosos Centrais/efeitos adversos , Angiografia Digital/instrumentação , Animais , Cateterismo Venoso Central/instrumentação , Meios de Contraste/administração & dosagem , Masculino , Camundongos , Camundongos Endogâmicos C57BL
17.
Eur J Radiol ; 84(5): 884-91, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25650332

RESUMO

OBJECTIVES: To evaluate the clinical feasibility of dual-source dual-energy CT angiography (DSDECTA) with virtual non-enhanced images and iodine map for active gastrointestinal bleeding (GIB). METHODS: From June 2010 to December 2012, 112 consecutive patients with clinical signs of active GIB underwent DSDECTA with true non-enhanced (TNE), arterial phase with single-source mode, and portal-venous phase with dual-energy mode (100 kVp/230 mAs and Sn 140 kVp/178 mAs). Virtual non-enhanced CT (VNE) image sets and iodine map were reformatted from 'Liver VNC' software. The mean CT number, noise, signal to noise ratio (SNR), image quality and radiation dose were compared between TNE and VNE image sets. Two radiologists, blinded to clinical data, interpreted images from DSDECTA with TNE (protocol 1), and DSDECTA with VNE and iodine map (protocol 2) respectively, with discordant interpretation resolved by consensus. The standards of reference included digital subtraction angiography, endoscopy, surgery, or final pathology reports. Receiver-operating characteristic (ROC) analysis was undertaken and the area under the curve (AUC) calculated for CT protocols 1 and 2, respectively. RESULTS: There was no significant difference in mean CT numbers of all organs (including liver, pancreas, spleen, kidney, abdominal aorta, and psoas muscle) (P>0.05). Lower noise and higher SNR were found on VNE images than TNE images (P<0.05). Image quality of VNE was lower than that of TNE without significant difference (P>0.05). The active GIB source was identified in 84 patients, 83 (83/84, 98.8%) of which were confirmed by one or more reference standard. The AUC was 0.935±0.027 and 0.947±0.026 for protocols 1 and 2, respectively. There was no significant difference between protocols 1 and 2 for diagnostic performance (Z=1.672, P>0.05). The radiation dose reduction achieved by omitting the TNE acquisition was (30.11±6.32)%. CONCLUSION: DSDECTA with arterial phase with single-source mode, portal-venous phase with dual-energy mode and post-processing VNE image sets and iodine map could act as an accurate screening method for detection and localization of active GIB with lower radiation dose.


Assuntos
Angiografia Digital/instrumentação , Meios de Contraste , Hemorragia Gastrointestinal/diagnóstico por imagem , Iodo , Veia Porta/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Angiografia Digital/métodos , Área Sob a Curva , Endoscopia Gastrointestinal , Estudos de Viabilidade , Feminino , Hemorragia Gastrointestinal/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Veia Porta/patologia , Valor Preditivo dos Testes , Curva ROC , Doses de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Índice de Gravidade de Doença , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
18.
J Invasive Cardiol ; 27(1): 20-6, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25589696

RESUMO

INTRODUCTION: Carbon dioxide (CO2) has been validated as a contrast agent in a large series of studies. A particular advantages of CO2 over iodinated contrast medium (ICM) is the absence of nephrotoxicity and allergic reactions. One of the limitations of CO2 angiography is the difficulty of CO2 manual injection due to its compressibility. The manual gas injection does not permit optimal control of the gas output. Development of an automated CO2 injector has overcome these problems. AIM: This study compares the feasibility, safety, and diagnostic accuracy of automated CO2 digital subtraction angiography (DSA) in comparison with ICM-DSA in the evaluation of critical limb ischemic (CLI) patients. METHODS: We performed DSA with both CO2 and ICM on 40 consecutive CLI patients and directly compared the two techniques. Sixteen females and 24 males participated in the study (mean age, 71.7 years). We assessed the diagnostic accuracy of CO2 in identifying arterial stenosis in the lower limb, with ICM-DSA used as the gold standard. RESULTS: The overall diagnostic accuracy of CO2-DSA was 96.9% (sensitivity, 99.0%; specificity, 96.1%; positive predictive value, 91.1%; negative predictive value, 99.6%). Tolerable minor symptoms occurred in 3 patients. No allergic reactions or significant decline in renal function were observed in patients receiving the CO2 injection. CONCLUSION: Carbon dioxide DSA is a valuable and safe alternative to traditional ICM-DSA for evaluating CLI patients. This modality should be considered as the standard choice for CLI patients undergoing angiographic evaluation who are known to have renal insufficiency or contrast allergy.


Assuntos
Angiografia Digital , Artérias/patologia , Dióxido de Carbono/farmacologia , Extremidade Inferior/irrigação sanguínea , Doença Arterial Periférica/diagnóstico , Idoso , Angiografia Digital/instrumentação , Angiografia Digital/métodos , Pesquisa Comparativa da Efetividade , Meios de Contraste/farmacologia , Precisão da Medição Dimensional , Estudos de Viabilidade , Feminino , Humanos , Injeções Intra-Arteriais/instrumentação , Injeções Intra-Arteriais/métodos , Compostos de Iodo/farmacologia , Masculino
19.
J Magn Reson Imaging ; 41(4): 1157-62, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24797218

RESUMO

PURPOSE: To develop a high temporal resolution MR imaging technique that could be used with magnetically assisted remote control (MARC) endovascular catheters. MATERIALS AND METHODS: A technique is proposed based on selective intra-arterial injections of dilute MR contrast at the beginning of a fluoroscopic MR angiography acquisition. The initial bolus of contrast is used to establish a vascular roadmap upon which MARC catheters can be tracked. The contrast to noise ratio (CNR) of the achieved roadmap was assessed in phantoms and in a swine animal model. The ability of the technique to permit navigation of activated MARC catheters through arterial branch points was evaluated. RESULTS: The roadmapping mode proved effective in phantoms for tracking objects and achieved a CNR of 35.7 between the intra- and extra-vascular space. In vivo, the intra-arterial enhancement strategy produced roadmaps with a CNR of 42.0. The artifact produced by MARC catheter activation provided signal enhancement patterns on the roadmap that experienced interventionalists could track through vascular structures. CONCLUSION: A roadmapping approach with intra-arterial contrast-enhanced MR angiography is introduced for navigating the MARC catheter. The technique mitigates the artifact produced by the MARC catheter, greatly limits the required specific absorption rate, permits regular roadmap updates due to the low contrast agent requirements, and proved effective in the in vivo setting. Inc.


Assuntos
Angiografia Digital/instrumentação , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Cateterismo Periférico/instrumentação , Angiografia por Ressonância Magnética/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
20.
Neuroradiol J ; 27(6): 710-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25489895

RESUMO

Shunting vascular malformations of the brain and spinal cord are traditionally studied using digital subtraction angiography (DSA), the current gold standard imaging method routinely used because of its favourable combination in terms of spatial and temporal resolution. Because DSA is relatively expensive, time-consuming and carries a risk of silent embolic events and a small risk of transient or permanent neurologic deterioration, a non-invasive alternative angiographic method is of interest. New 320 row-detector CT scanners allow volumetric imaging of the whole brain with temporal resolution up to ≌ 3 Hz. Those characteristics make computed tomography angiography (CTA) an affordable imaging method to study the haemodynamics of the whole brain and can also be applied to the study of limited portions of the spinal cord. The aim of this paper is to make a brief summary of our experience in studying shunting vascular malformation of the brain and spinal cord using dynamic 4D-CTA, explaining the technical details of the studies performed at our institution, and the state-of-the-art major advantages and drawbacks of this new technique. We found that dynamic 4D-CTA is able to depict the main architectural characteristics of previously untreated vascular shunting malformations both in brain and spinal cord (i.e. their main arterial feeders and draining veins) allowing their correct diagnosis and exhaustive classification, limiting the use of DSA for therapeutic purposes.


Assuntos
Angiografia Digital/métodos , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada Quadridimensional/métodos , Angiografia Digital/instrumentação , Angiografia por Tomografia Computadorizada/instrumentação , Tomografia Computadorizada Quadridimensional/instrumentação , Humanos